Series 34 Sanitary Dio-Seal Isolator
  • Overview
  • Applications
  • Dimensions
  • Construction
  • Installation
  • Ordering
  • Series 34 Sanitary Dio-Seal Isolator Installation

    The sanitary isolator is designed to mate with the Tri-Clamp pipe sections. Flange gaskets are not used since the Sensor Ring contains integrally molded Tri-Clamp gaskets. Use appropriate sanitary clamps to secure isolator in pipeline, applying normal tightening torque to assure a leak-free installation. This integral gasket design facilitates factory calibration and ensures accuracy in field installation.

    The annular volume between isolator body and Sensor Ring and the instrument internal volume are filled with a food grade Sensor Fluid, providing the hydraulic link required to transfer the process pressure signal to the instrument. The Sensor Fluid must be compatible with the Sensor Ring material and the process fluid.

    Working pressure is nominally the Tri-Clamp pressure rating at the process operating temperature. The isolator can be operated up to the maximum allowable temperature rating of the Sensor Ring material. For verification of allowable temperature ratings, consult Factory.

    To print out this and other important information, click