Series 22 Dia-Cam Pinch Valve Operation
|
Manual operation of the valve is accomplished with a
7-position notched detent plate and spring-loaded
lever assembly. Automated Operation is achieved by
assembling any pneumatic or electric quarter-turn
actuator control package to the stem, using a properly
fitted coupling and bracket. Tapped mounting holes are
provided for assembling the bracket to the valve.
Maximum working pressure for all sizes is 125 psig.
Operating temperature is -40 to 275ºF depending on the
elastomer system used in the valve. For
throttling applications, proper valve sizing involves
determining the Cv required, taking into consideration
fluid viscosity, pipeline size and cavitation potential.
Consult Factory for sizing verification.
|
To print out this and other important information, click |
|